MENU
Toggle navigation
Products
FreeStyle 8400™ Interlocking Floor System
ESD Vinyl Tile
8400 Series Conductive ESD Vinyl Tile
8400 Series Dissipative ESD Vinyl Tile
FreeStyle 8400 Interlocking Flooring System
7900 Series Conductive ESD Vinyl Tile
Modular Conductive Interlocking Floor Tile
ESD Modular Carpet Tiles
Colonial Series
Discovery Eco Series
Landmark Series
Presidential Series
Adhesive and Grounding Strips
Conductive Rubber Tiles and Rolls
Conductive Adhesive, Grounding and Weld Rod
Dissipative Floor Finishes
Statguard® Low-VOC Dissipative Floor Finish
Statguard® Dissipative Floor Finish
Statguard® Floor Label
ESD Floor Maintenance Products
Statguard® Floor Stripper
Statguard® Floor Neutralizer
Statguard® ESD Floor Cleaner
Statfree® Dissipative Spray Buff
Statfree® Burnishing Restorer
Measurement Meters
Conductive Epoxy
Charge-Guard™ Conductive Epoxy
Statguard Conductive Epoxy
New Products
Resources
Partners
Webinar
Videos
REGISTER / LOGIN
SHOP
CART (
0
)
SUBSCRIBE TO OUR EMAIL LIST - Be the first to know
about exclusive deals, tips, new products & more!
Questions And Answers
#
196
List All Questions
Search
List by Category
Question
When taking measurements from our LCD megohmeter and using the 5 lb. electrodes, we measured 1.8 x 10^8 Ohm/sq. on his dissipative table laminate. After inserting a foam disc of 1/4" height and 2" diameter (apparently impregnated with carbon, surface resistivity: 10^4 Ohm/sq.) between one of the electrodes and the table surface, we measured 3.4 x 10^7 Ohm/sq. Can you offer any explanation as to why surface resistivity would decrease upon inserting a conductive object between a dissipative surface and the electrode? It seems to counter common sense but it is the fact. - Anonymous, Born, Germany
Answer
There are two phenomena happening here. One is polarization. Every time you make a measurement, you drive a current between the probes and depending on the material and the potential (100 Volts) you may polarize the conductive elements (aligning them up…making the path between the probes even more conductive…..they may relax after a while though). Second is a possible increase to the surface contact. The rubber pad on the bottom of our 5 lb probes is less then 10 ohms, but not as soft as the foam. The foam, when compressed with a 5 lb probe, may make more surface contact (contact more of the 2” diameter surface) then just the rubber pad by itself. This in turn will decrease the contact resistance and yield a lower resistance reading.