MENU
Toggle navigation
Products
FreeStyle 8400™ Interlocking Floor System
ESD Vinyl Tile
8400 Series Conductive ESD Vinyl Tile
8400 Series Dissipative ESD Vinyl Tile
FreeStyle 8400 Interlocking Flooring System
7900 Series Conductive ESD Vinyl Tile
Modular Conductive Interlocking Floor Tile
ESD Modular Carpet Tiles
Colonial Series
Discovery Eco Series
Landmark Series
Presidential Series
Adhesive and Grounding Strips
Conductive Rubber Tiles and Rolls
Conductive Adhesive, Grounding and Weld Rod
Dissipative Floor Finishes
Statguard® Low-VOC Dissipative Floor Finish
Statguard® Dissipative Floor Finish
Statguard® Floor Label
ESD Floor Maintenance Products
Statguard® Floor Stripper
Statguard® Floor Neutralizer
Statguard® ESD Floor Cleaner
Statfree® Dissipative Spray Buff
Statfree® Burnishing Restorer
Measurement Meters
Conductive Epoxy
Charge-Guard™ Conductive Epoxy
Statguard Conductive Epoxy
New Products
Resources
Partners
Webinar
Videos
REGISTER / LOGIN
SHOP
CART (
0
)
SUBSCRIBE TO OUR EMAIL LIST - Be the first to know
about exclusive deals, tips, new products & more!
Questions And Answers
#
325
List All Questions
Search
List by Category
Question
Wanted to find out the difference in ESD effectiveness of using a cloth ESD wrist strap versus a metal, expansion board. It seems to me that the metal, expansion band would be better at eliminating static build-up than the cloth strap, due to a larger conductive surface area. - Anonymous, Fresenius Medical Care-North America, Walnut Creek, CA
Answer
The key to personal grounding is to have an adequate path to ground so that there is never a potential difference with respect to ground on the human body at times longer than 150 ms body movement time. This is accomplished well with either the cloth or metal expansion wrist strap. The resistance of the cloth strap is typically under 1 kilohm (I measured 400 ohms on one in the lab) which is more than adequate to derive a discharge time well under 150 ms, in fact is well under 2 microseconds, which is more than adequate. In both cases (metal expansion and cloth wrist straps) the total discharge time is mainly influenced by the skin's resistance, the contact resistance to the band/buckle, and the body/band capacitance to ground. Using either band, the human body is more than adequately protected from it's ground connection via the wrist strap. The concern is if the band's resistance or equivalent resistance of the body to band starts to exceed 1x10
8
ohms. Most wrist strap testers fail high over 1x10
7
ohms.