MENU
Toggle navigation
Products
FreeStyle 8400™ Interlocking Floor System
ESD Vinyl Tile
8400 Series Conductive ESD Vinyl Tile
8400 Series Dissipative ESD Vinyl Tile
FreeStyle 8400 Interlocking Flooring System
7900 Series Conductive ESD Vinyl Tile
Modular Conductive Interlocking Floor Tile
ESD Modular Carpet Tiles
Colonial Series
Discovery Eco Series
Landmark Series
Presidential Series
Adhesive and Grounding Strips
Conductive Rubber Tiles and Rolls
Conductive Adhesive, Grounding and Weld Rod
Dissipative Floor Finishes
Statguard® Low-VOC Dissipative Floor Finish
Statguard® Dissipative Floor Finish
Statguard® Floor Label
ESD Floor Maintenance Products
Statguard® Floor Stripper
Statguard® Floor Neutralizer
Statguard® ESD Floor Cleaner
Statfree® Dissipative Spray Buff
Statfree® Burnishing Restorer
Measurement Meters
Statguard® Conductive Epoxy
New Products
Resources
Partners
Webinar
Videos
REGISTER / LOGIN
SHOP
CART (
0
)
SUBSCRIBE TO OUR EMAIL LIST - Be the first to know
about exclusive deals, tips, new products & more!
Questions And Answers
#
1052
List All Questions
Search
List by Category
Question
We are using a protective ESD floor wax, heel straps, table mats, and wrist straps. I just wanted to verify the proper configuration of using all these systems in conjunction with one another. Our wrist jacks are grounded to an electrical outlet (no resistor), wrist straps cords have a 1 megohm resistor, table mats have a 1 megohm resistor ground cord that is grounded to the same point as the wrist jacks. Our personnel are wearing 2 heel straps with resistors on an ESD waxed floor. Is this a common set up? I am getting the impression that this may be overkill? We are handling circuit boards and various computer components. Do I need this many resistors? Can there be a disadvantage to this type of set-up? - Anonymous, San Diego, CA,
Answer
The ESD control program that you describe is typical of companies’ dealing with Human Body Model ESDS Component Classification Class 0 or less than 250 Withstand Voltage. However, I believe that ESD dissipative floor finish, like Statproof® is a polymer, not a wax which would be insulative. Our Wrist Straps and Foot Grounders are UL listed having a 1 or 2 megohm resistor included. This is not for ESD control, but to protect the user in case of inadvertent contact with electrical line voltage up to 250 volts. Many ESD control programs are driven by meeting the company’s written ESD control plan, or meeting customer or ISO audits. Ideally, however, expenditures for ESD control would be driven by your company’s efforts to improve quality, productivity and customer satisfaction. If you are approaching zero quality defects, you should consider saving money by scaling back ESD control requirements. The primary area where money is wasted or saved involves ESD caused latent defects that wound the electronic component at one stage while passing all inspections, but then subsequently failing at a later assembly stage or even when the product is in the hands of the customer. Particularly, when the product works intermittently, these quality problems can be very annoying, mysterious, and costly.
Related Categories:
ESD
ESD Control Program
Resistance
Workstations
If you have found this Q/A useful, please rate it based on its helpfulness.