MENU
Toggle navigation
Products
FreeStyle 8400™ Interlocking Floor System
ESD Vinyl Tile
8400 Series Conductive ESD Vinyl Tile
8400 Series Dissipative ESD Vinyl Tile
FreeStyle 8400 Interlocking Flooring System
7900 Series Conductive ESD Vinyl Tile
Modular Conductive Interlocking Floor Tile
ESD Modular Carpet Tiles
Colonial Series
Discovery Eco Series
Landmark Series
Presidential Series
Adhesive and Grounding Strips
Conductive Rubber Tiles and Rolls
Conductive Adhesive, Grounding and Weld Rod
Dissipative Floor Finishes
Statguard® Low-VOC Dissipative Floor Finish
Statguard® Dissipative Floor Finish
Statguard® Floor Label
ESD Floor Maintenance Products
Statguard® Floor Stripper
Statguard® Floor Neutralizer
Statguard® ESD Floor Cleaner
Statfree® Dissipative Spray Buff
Statfree® Burnishing Restorer
Measurement Meters
Conductive Epoxy
Charge-Guard™ Conductive Epoxy
Statguard Conductive Epoxy
New Products
Resources
Partners
Webinar
Videos
REGISTER / LOGIN
SHOP
CART (
0
)
SUBSCRIBE TO OUR EMAIL LIST - Be the first to know
about exclusive deals, tips, new products & more!
Questions And Answers
#
1132
List All Questions
Search
List by Category
Question
Hi. Is it mandatory to keep the humidity RH SPEC inside hygrometer similar to ANSI/ESD S20.20 requirement >30% but less than 70%? IF yes . Why? Would appreciate your comments and shared of thoughts. Many thanks - Anonymous, kulim, 00, Malaysia
Answer
As you note, the ESD Association in ANSI/ESD S20.20 Table 1 has Humidity Technical Requirement as > 30% Rh < 70%, however this is the minimum recommended technical requirement, so it is recommended. Note 6 states “This is a proposed value that has not been substantiated by any standard.”
In Malaysia, high charge generation due to low humidity isn’t likely a problem; tribocharging reduces significantly at higher humidity; however the concern is corrosive effects on electronic components.
From ESD Handbook TR 20.20 paragraph 5.3.15 Humidity
“Humidity is beneficial in all ESD Control Program Plans. Contact and separation of dry materials generates greater electrostatic charges than moist materials because moisture provides conductivity that helps to dissipate charge. For this reason, ESD effects are most noticeable in the winter since heating systems reduce building environment moisture. Geographic location (desert vs. coastland) is also a major contributor to ambient conditions inside buildings. Any circumstance that results in a low relative humidity will permit a greater accumulation of electrostatic charges. Relative humidity above 30 percent in ESD protective areas is desirable as long as other adverse conditions are not created as a result of humidity levels. Generally speaking an upper limit of 70 percent is desirable to prevent corrosive effects on the metal portions of electronic devices and assemblies.”
Your ESD Control Plan can set a different range that the recommended greater than 30% RH and less than 70%. Per S20.20 paragraph 6.0.3. Tailoring:
“This document, or portions thereof, may not apply to all applications. Tailoring is accomplished by evaluating the applicability of each requirement for the specific application. Upon completion of the evaluation, requirements may be added, modified or deleted. Tailoring decisions, including rationale, shall be documented in the ESD Control Program Plan”
Related Categories:
Charge Generators
ESD
Humidity
ANSI/ESD S20.20