MENU
Toggle navigation
Products
FreeStyle 8400™ Interlocking Floor System
ESD Vinyl Tile
8400 Series Conductive ESD Vinyl Tile
8400 Series Dissipative ESD Vinyl Tile
FreeStyle 8400 Interlocking Flooring System
7900 Series Conductive ESD Vinyl Tile
Modular Conductive Interlocking Floor Tile
Conductive Rubber Tiles and Rolls
Conductive Adhesive, Grounding and Weld Rod
Dissipative Floor Finishes
Statguard® Low-VOC Dissipative Floor Finish
Statguard® Dissipative Floor Finish
Statguard® Floor Label
ESD Floor Maintenance Products
Statguard® Floor Stripper
Statguard® Floor Neutralizer
Statguard® ESD Floor Cleaner
Statfree® Dissipative Spray Buff
Statfree® Burnishing Restorer
Measurement Meters
Conductive Epoxy
Charge-Guard™ Conductive Epoxy
Statguard Conductive Epoxy
New Products
Resources
Partners
Webinar
Videos
REGISTER / LOGIN
SHOP
CART (
0
)
SUBSCRIBE TO OUR EMAIL LIST - Be the first to know
about exclusive deals, tips, new products & more!
Questions And Answers
#
246
List All Questions
Search
List by Category
Question
The products my company works on are SGI computers. We occasionally have to remove the system boards, and install CPUs or Memory. I have currently been tasked with establishing an ESD area for our company. I have purchased table mats, wrist straps and wrist strap monitors. I have marked the area clearly with color-coded tape on the floor, as well as hanging signs declaring the area as an ESD area. Are there any other steps I need to do to ensure the area are set up correctly? - Ralph Brandt, Rosses Medical, Columbia, MD
Answer
Even if you make the assumption that all devices are class 0, there are still a few things that need to be addressed. All ESD sensitive components coming into the area need be in sealed ESD protective packaging, if not, they may already have been damaged upstream from your ESD safe work area. All employees handling ESD sensitive devices in the ESD safe work area need to be properly trained, so they know how/why to wear their wrist strap, how to test it, when to wear it, how to handle ESD sensitive devices including the opening of ESD packages. Your vendors supplying ESD sensitive devices need to both handle them correctly and package them correctly. Control the necessary insulators at your ESD safe work area with ionization or topical ESD treatments. Remove unnecessary insulators from your ESD safe work area. Check the integrity of your ESD ground, common point ground Make sure an operator doesn't come in more than 12 inches from an ESD sensitive device before donning their wrist strap (make it easy to plug in at front of bench) Set up and monitor scheduled auditing of your ESD safe work area to ensure all items are in compliance, including the operators training.
Related Categories: