MENU
Toggle navigation
Products
FreeStyle 8400™ Interlocking Floor System
ESD Vinyl Tile
8400 Series Conductive ESD Vinyl Tile
8400 Series Dissipative ESD Vinyl Tile
FreeStyle 8400 Interlocking Flooring System
7900 Series Conductive ESD Vinyl Tile
Modular Conductive Interlocking Floor Tile
ESD Modular Carpet Tiles
Colonial Series
Discovery Eco Series
Landmark Series
Presidential Series
Adhesive and Grounding Strips
Conductive Rubber Tiles and Rolls
Conductive Adhesive, Grounding and Weld Rod
Dissipative Floor Finishes
Statguard® Low-VOC Dissipative Floor Finish
Statguard® Dissipative Floor Finish
Statguard® Floor Label
ESD Floor Maintenance Products
Statguard® Floor Stripper
Statguard® Floor Neutralizer
Statguard® ESD Floor Cleaner
Statfree® Dissipative Spray Buff
Statfree® Burnishing Restorer
Measurement Meters
Conductive Epoxy
Charge-Guard™ Conductive Epoxy
Statguard Conductive Epoxy
New Products
Resources
Partners
Webinar
Videos
REGISTER / LOGIN
SHOP
CART (
0
)
SUBSCRIBE TO OUR EMAIL LIST - Be the first to know
about exclusive deals, tips, new products & more!
Questions And Answers
#
271
List All Questions
Search
List by Category
Question
When using a painted metal cart having insulative wheels and a drag chain to ground, what is the recommended practice for removing ESDS components? If the components are kept inside the original packaging i.e.: tape and reel, tube or tray, can the components be damaged due to ESD when removed from the carts? - Anonymous, Chino, CA
Answer
Assuming that if the carts are metal and painted with ESD paint and the floor is ESD conductive then the only concern would be the handling of the components by an ungrounded (charged) operator as not all packaging mentioned is known to be ESD safe. Especially if the operator is removing components from the manufacturer’s packaging, these packages, if ESD dissipative, should be placed on a grounded dissipative work mat before opening them. Also request that your supplier put ESD sensitive items into shielding bags so that when they are to be handled and transported, they will be protected when away from an ESD Safe work station.