MENU
Toggle navigation
Products
FreeStyle 8400™ Interlocking Floor System
ESD Vinyl Tile
8400 Series Conductive ESD Vinyl Tile
8400 Series Dissipative ESD Vinyl Tile
FreeStyle 8400 Interlocking Flooring System
7900 Series Conductive ESD Vinyl Tile
Modular Conductive Interlocking Floor Tile
ESD Modular Carpet Tiles
Colonial Series
Discovery Eco Series
Landmark Series
Presidential Series
Adhesive and Grounding Strips
Conductive Rubber Tiles and Rolls
Conductive Adhesive, Grounding and Weld Rod
Dissipative Floor Finishes
Statguard® Low-VOC Dissipative Floor Finish
Statguard® Dissipative Floor Finish
Statguard® Floor Label
ESD Floor Maintenance Products
Statguard® Floor Stripper
Statguard® Floor Neutralizer
Statguard® ESD Floor Cleaner
Statfree® Dissipative Spray Buff
Statfree® Burnishing Restorer
Measurement Meters
Statguard® Conductive Epoxy
New Products
Resources
Partners
Webinar
Videos
REGISTER / LOGIN
SHOP
CART (
0
)
SUBSCRIBE TO OUR EMAIL LIST - Be the first to know
about exclusive deals, tips, new products & more!
Questions And Answers
#
857
List All Questions
Search
List by Category
Question
Should ESD smocks and Foot straps be worn outside during an electrical/lightning storms. Is this a safe practice? I THINK NOT. Please advise ASAP, we have a very dangerous issue on hand, and I need all the data sent to me via-e-mail if at all possible. NOTE: The smocks and straps are supposed to have a 10meg or a 1,000,000 ohm resistor built into them. I really do not think that makes much of a difference. Your input on this issue would be very valuable to me, and Intel, and may help save a lot of lives. - Anonymous, Portland, OR
Answer
The safety of the operator always comes first. Grounding personnel is only for controlled areas such as ESD Safe areas. When personnel leave these areas and may encounter high voltage/current such as at High-Pot stations, exposed electrical wiring, working around high voltage equipment such as Ion Implanters, Electron Beam Lithography, outside in electrical storms, ect. In these instances, the company’s Safety Officer should be consulted and procedures developed base on the safety of the operator being priority one. We would not recommend grounding personnel when working with voltages over 250 VAC or 500 VDC nor when outside in a lightning storm, as described in the Cenelec Electronic Components Committee standard section 4.1.1, CECC 00015/I. Both our foot grounders and wrist straps employ a 1/4 Watt carbon composite resistor rated 250 Volts Alternating Current (VAC) and UL tested and listed for voltages under 250 VAC.
Related Categories:
Health & Safety
If you have found this Q/A useful, please rate it based on its helpfulness.
This question has been rated:
(